Manufacture
|
Product
|
Ingredients
|
Physical
Data
|
Fire
Hazard
|
Health
Hazard
|
Treatment
|
Spill
Procedures
|
Protection
|
Precautions
|
| USG |
Ready
Mixed Joint Treatment and W/R Compound |
Limestone,
Mica, Talc, Perlite, Clay, and other inert products. |
Off
white paste, low odor |
None |
Dust
may irritate eyes, nose, throat and upper respiratory system. May
dry skin. Long term inhalation may cause lung damage. |
Flush
eyes with plenty of water. Wash skin with soap and water. If irritation
continues, consult physician. |
Scoop
up, Wash down before material dries. Deposit in proper landfill. |
Wear
NIOSH approved dust respirator when dry sanding. Ventilate area
and wear safety glasses or goggles. |
Avoid
freezing. |
| USG |
Powder Joint
Compound Setting Type and Firecode Compound
|
Plaster
of Paris, Limestone, Mica, Clay, Perlite, and other inert products. |
Powder
to mix as paste |
None |
Dust
may irritate eyes, nose, throat and upper respiratory system. May
dry skin. Long term inhalation may cause lung damage.When mixed
with water, this material hardens and slowly becomes hot. Do not
make a cast enclosing any part of the body. |
Flush
eyes with plenty of water. Wash skin with soap and water. If irritation
continues, consult physician. Call physician if ingested as material
hardens and may cause obstruction. |
Scoop
up, Wash down before material dries. May plug drains as it hardens.
Deposit in proper landfill. |
Wear
NIOSH approved dust respirator when dry sanding. Ventilate area
and wear safety glasses or goggles. |
Keep
dry or material may harden. |
| Lincoln |
Flux
Coated Electrode |
Aluminum,
Magnesium, Silicon. |
Rod |
None |
Fumes
are hazardous and can cause lung damage after prolonged exposure.
Electric shock can kill. Do not operate around damp areas. |
If
shocked, call medical aid and employ CPR. Work in ventilated areas
only. |
|
Wear
welding hood or face shield, gloves, and protective clothing. |
Watch
danger of electric shock. |
| US
Steel |
Metal Studs and Track |
Iron,
Aluminum, Carbon, Sulfur, Oil Coating |
Iron
|
None
|
Metal
itself is not hazardous, however, protect yourself from cutting
or burning metals. |
Ventilate
area where metal is cut. |
x |
Wear
protective eye wear and clothing when cutting or fastening metal.
|
Avoid
metal fumes or dust. Watch for shock hazards. |
| Mobil
Oil |
Cutting
Oil |
Petroleum
|
Liquid,
Mild odor |
Flammable
|
For
oil mist, slight eye/skin irritation. |
Flush
eyes with plenty of water. Wash skin with soap and water. |
Absorb
on fire retardant sawdust, or dirt. |
No
special protection. |
Use
in ventilated areas. |
| USG
|
First
Coat |
Water,
Clay, Polyvinyl, Ethylene Glycol and inert products. |
White
Liquid |
None
|
Spray
mist may irritate eyes, nose, throat and upper respiratory system.
May dry skin. Long term inhalation may cause lung damage. |
Flush eyes with plenty of water. Wash skin with soap and water.
If irritation continues, consult physician. |
Soak
up, Wash down before material dries. Deposit in proper landfill.
|
Wear
NIOSH approved dust respirator when dry sanding. Ventilate area
and wear safety glasses or goggles. |
Wet-sanding
is recommended. Avoid freezing. |
| USG
Hilti |
Acoustical
Sealant and Firestop Sealant. |
Limestone,
Butyl acrylate, Ethylene glycol |
Medium
Paste |
None
|
May
irritate eyes or skin. Harmful fumes if inhaled. |
Flush
eyes with plenty of water. Wash skin with soap and water. If irritation
continues, consult physician. |
Scoop
up, Wash down before material dries. May plug drains as it hardens.
Deposit in proper landfill. |
Ventilate
area and wear safety glasses or goggles. |
Avoid
prolonged contact. |
| USG
|
Durock
Cement Board |
Slag,
Cement, Clay, Gypsum, inert products |
Gray
board, mild odor |
None
|
Do
not breath dust if cut with power saw. Dust can irritate lungs and
eyes. |
Ventilate
area where board is cut. Flush eyes with plenty of water. Wash skin
with soap and water. Wear NIOSH approved dust respirator when cutting.
|
x
|
Wear
protective eye wear and clothing when cutting or fastening and clothing
when cutting or fastening. |
Keep
clean, dry and flat. |
| Hilti
|
Spray |
|
Lubricant
Liquid with odor of kerosene |
Flammable |
Mineral
oils are suspected carcinogens of. Skin and lungs. Harmful fumes
if excessive inhaled. |
Flush eyes with plenty of water. Wash skin with soap and water.
If irritation continues, consult doctor. |
Remove
sources of ignition. |
Safety
glasses and gloves recommended. |
|
|
Hilti |
Powerloads |
Gun
powder |
Brass
casing |
Unusual
Fire and Explosion Hazard |
May
irritate eyes and skin with prolonged exposure. |
Flush
with plenty of water. Wash skin with soap and water. |
Do
not crush or drop. Keep away from heat. |
Wear
safety glasses and protective clothing. |
Use in proper tools that are maintained. Dispose of misfires and
bent cartridges in a water and detergent container. |
| Hilti |
HEA
|
Epoxy
Styrene, Vinyl Resin |
Sealed
glass tube |
Flammable |
Contact causes eye burns and skin irritation. Can have an anesthetic
effect if inhaled. Can cause allergic skin and respiratory reactions. |
Flush eyes with plenty of water. Wash skin with soap and water.
Contact physician if prolonged symptoms. Remove sources of ignition.
|
Remove
broken tubes. |
Wear
protective safety glasses and clothing. |
Keep
cool and dry and away from heat. |
| USG |
Thermafiber |
Mineral
wool fiber |
Mineral
fiber felt, low odor |
None |
Mineral fiber may cause irritation to eyes and skin or lungs. |
Flush eyes with plenty of water. Wash skin with soap and water.
If irritation continues, consult physician. |
Normal
clean up. Deposit in proper landfill. |
Wear
NIOSH approved dust respirator when dry sanding. Ventilate area
and wear safety glasses or goggles. |
Wear
gloves and loose clothing to avoid skin irritation. |
| USG/GP/
Pabco/Gold Bond |
Gypsum
Board |
Gypsum,
Limestone, Vermiculite, Clay |
Board
|
None
|
When cut with power tools, the dust may cause eye irritations and
lung irritation. |
Flush
eyes with plenty of water. Wash skin with soap and water. If irritation
continues, consult physician. |
Deposit
in proper landfill. |
Wear
protective safety glasses and clothing. |
Store
dry and flat. When wet, gypsum board will lose strength, but will
regain strength upon drying. |
| Hilti |
Firestop
Joint Spray |
No
hazardous ingredients. |
Viscous
red paste, mild odor. |
None |
Irritation
is possible. Chronic: Non known. |
Flush
eyes, wash skin with soap & water, Do not induce vomiting if ingested. |
Wipe up spills
immediately. Not a hazardous waste.
|
Use chemical goggles when spraying, safety goggles at a minimum,
gloves. |
Store cool and dry, do not freeze. Ventilate well. |